DC6038F 60x60x38mm High-Pressure DC Fan
A 38mm deep 60mm fan for high-impedance server, telecom and power-electronics airflow paths.
Built around a 60x60x38mm frame, DC6038F targets applications where installation area is limited but system resistance is severe. Five performance levels extend to 17,500RPM, 69.21CFM and 93.54mmH2O, with 12V, 24V and 48V variants for different power architectures.
Rated Voltage: 12V / 24V / 48V
Size: 60x60x38mm
Max Airflow: 69.21CFM
Max Static Pressure: 93.54mmH2O
Rated Speed: 17,500RPM
Noise Range: 65.70dBA
12V, 24V and 48V Deep-Frame Fan Options
Compare DC6038F by voltage, speed, airflow, static pressure, current, noise and bearing type. Select the required model from the full published specification table rather than choosing only by maximum airflow.
| Model | Bearing Type | Rate Voltage(VDC) | Current (A) | Speed (RPM) | Air Flow (CFM) | Static Pressure (mmH₂O) | Noise Level (dBA) | Weight (g) |
|---|---|---|---|---|---|---|---|---|
| YDU6038B12F | B | 12 | 1.50 | 15000 | 57.51 | 63.76 | 63.10 | 105 |
| YDH6038B12F | B | 12 | 1.20 | 13500 | 51.76 | 51.65 | 60.80 | 105 |
| YDM6038B12F | B | 12 | 0.88 | 12000 | 46.01 | 40.81 | 58.30 | 105 |
| YDL6038B12F | B | 12 | 0.65 | 10500 | 40.26 | 31.24 | 55.40 | 105 |
| YDU6038B24F | B | 24 | 0.75 | 15000 | 57.51 | 63.76 | 63.10 | 105 |
| YDH6038B24F | B | 24 | 0.58 | 13500 | 51.76 | 51.65 | 60.80 | 105 |
| YDM6038B24F | B | 24 | 0.45 | 12000 | 46.01 | 40.81 | 58.30 | 105 |
| YDL6038B24F | B | 24 | 0.35 | 10500 | 40.26 | 31.24 | 55.40 | 105 |
| YDU6038B48F | B | 48 | 0.41 | 15000 | 57.51 | 63.76 | 63.10 | 105 |
| YDH6038B48F | B | 48 | 0.32 | 13500 | 51.76 | 51.65 | 60.80 | 105 |
| YDM6038B48F | B | 48 | 0.25 | 12000 | 46.01 | 40.81 | 58.30 | 105 |
| YDL6038B48F | B | 48 | 0.21 | 10500 | 40.26 | 31.24 | 55.40 | 105 |
High Static Pressure from a 60x60x38mm Frame
Its 38mm frame is designed around pressure capability, voltage flexibility and controlled integration.
38mm Frame Builds Pressure Headroom
Extra frame depth supports the impeller and motor arrangement needed for pressure-focused airflow in a compact 60mm opening.
Up to 93.54mmH2O Static Pressure
The highest published curve is intended for very restrictive paths; noise, current and operating point must be reviewed together.
12V, 24V and 48V Platforms
Three voltage families allow the same mechanical envelope to be evaluated across server, industrial and telecom power systems.
Feedback and Protection Functions
FG, RD, PWM, Auto Restart and Polarity Protection options support controlled integration rather than simple two-wire operation.
Deep-Frame 60mm Server Fan Overview
A 38mm installation depth separates DC6038F from standard 60mm fans. It is appropriate only when the chassis can accept that depth and the measured resistance justifies its higher pressure and acoustic output.
Glass-fiber-reinforced PBT impeller and housing are rated UL 94V-0. Available functions include FG, RD, PWM, Auto Restart and Polarity Protection; final wiring, connector, signal definition and bearing choice should be confirmed for the project.
Airflow and Pressure Curves up to 17,500RPM
The deep frame produces a distinctly higher pressure range, but the 10,000 to 17,500RPM choices also change current and noise. Plot or estimate the system-resistance line first, then select the lowest grade that still clears the required airflow at that intersection.

High-Resistance Cooling Uses for a 60mm Server Fan
This model belongs in designs where a standard-depth 60mm fan loses too much airflow against system resistance.
Get Fan Selection Support
High-Density Server Chassis
A deep 60mm fan can be considered where drive cages and heat sinks create strong impedance and the chassis accepts a 38mm depth.
Telecom Power Shelves
48V variants suit telecom power shelves and network equipment that require compact, pressure-oriented ventilation.
Inverter and Drive Cooling
Concentrated losses around power semiconductors and heat sinks often need airflow that remains effective after passing restrictive fins.
Filtered Industrial Enclosures
Pressure reserve can compensate for filter and grille losses, subject to loaded-filter testing and acceptable noise.
Directed Cooling Ducts
Short, narrow ducts can use DC6038F when bends and small outlets demand more pressure than a standard-depth 60mm fan.
60x60x38mm Server Fan Airflow and Sound Demonstration
Show the 38mm installation depth, airflow direction and operating sound of the exact voltage and speed grade. A short view of the restricted test path will make the pressure-oriented use case easier to understand.
Show the 38mm installation depth, airflow direction and operating sound of the exact voltage and speed grade. A short view of the restricted test path will make the pressure-oriented use case easier to understand.
60x60x38mm High-Pressure Fan FAQs
A: DC6038F uses a 60x60x38mm frame. Confirm mounting-hole spacing and clearance with the product drawing before installation.
A: Published options include 12V / 24V / 48V. Select the exact model according to rated voltage, current and controller compatibility.
A: The published range reaches 69.21CFM and 93.54mmH2O. Use the P-Q curve for the actual operating point.
A: FG, RD and PWM are listed as function options. Signal voltage, frequency, wiring and minimum duty must be confirmed before connection.
A: The product range lists ball bearing. Confirm the bearing code, operating temperature and expected service conditions with the selected model.
A: Project-specific voltage, speed, wire length, connector and control functions can be discussed. Performance must remain tied to an approved model and sample validation.

Can't Find the Perfect Fan?
We offer customization services from wire length to full mold design. Get a solution in 48 hours.
Get Fan Selection Support