70x70x20mm DC Fan DC7020
43.20CFM maximum free-air airflow in a 20mm-deep frame, with 12V and 24V versions for equipment ventilation.
Limited to a 70×70mm mounting footprint but need more air movement than a shallower solution? The DC7020 offers three defined speed grades in a 70×70×20mm axial format. Evaluate its 6.83mmH₂O maximum static-pressure rating together with the equipment air path, rather than selecting from CFM alone.
Rated Voltage: 12V / 24V
Size: 70×70×20mm
Max Airflow: 43.20CFM
Max Static Pressure: 6.83mmH₂O
Max Speed: 5,000RPM
12V and 24V Fan Specifications for DC7020
Specify this series by its full part number. The 5,000RPM versions reach 43.20CFM, while the 4,000RPM and 3,000RPM options offer lower airflow and noise values. Both voltage families retain the same outside dimensions; current requirements differ.
| Model | Bearing Type | Rate Voltage(VDC) | Current (A) | Speed (RPM) | Air Flow (CFM) | Static Pressure (mmH₂O) | Noise Level (dBA) |
|---|---|---|---|---|---|---|---|
| YDH7020X12 | S or B | 12 | 0.38 | 5000 | 43.20 | 6.83 | 41.50 |
| YDM7020X12 | S or B | 12 | 0.22 | 4000 | 34.56 | 4.37 | 36.60 |
| YDL7020X12 | S or B | 12 | 0.11 | 3000 | 25.92 | 2.46 | 30.40 |
| YDH7020X24 | S or B | 24 | 0.19 | 5000 | 43.20 | 6.83 | 41.50 |
| YDM7020X24 | S or B | 24 | 0.11 | 4000 | 34.56 | 4.37 | 36.60 |
| YDL7020X24 | S or B | 24 | 0.06 | 3000 | 25.92 | 2.46 | 30.40 |
Bearing code S or B denotes sleeve or ball-bearing alternatives. The listed functional options include FG, RD, PWM, auto restart and polarity protection; confirm the required option and connector for the actual ordered model.
43.20CFM Airflow and Practical 20mm Fan Design
The selection advantage lies in matching a fixed 70mm mounting area to the needed airflow, acoustic level and system resistance. Four considerations matter most for this 20mm-deep product family.
43.20CFM Maximum Airflow for Localized Heat
The 5,000RPM grade supplies up to 43.20CFM of free-air flow, providing an option for enclosures with a more demanding thermal load. This is a cataloged operating grade, not a prediction of airflow after a grille or heat sink is installed.
20mm Depth Within a 70mm Mounting Footprint
An extra 5mm of depth compared with a 15mm frame must be accounted for in the enclosure. It is relevant when a shallower fan cannot meet the required airflow but 25mm of internal clearance is unavailable.
Three Defined Airflow and Acoustic Grades
Choose among 25.92, 34.56 and 43.20CFM grades, corresponding to 30.40, 36.60 and 41.50dBA respectively. These values belong to different rated-speed models; they should not be presented as simultaneously adjustable performance on every fan.
Ventilation Options for Equipment Integration
FG, RD and PWM functions are available as configuration options alongside auto restart and polarity protection. Electrical interface, signal type and cable configuration should be matched to the host device before a final part number is confirmed.
YCCFAN 70×70×20mm Fan for Electronics Ventilation
A middle-depth option when a fixed fan opening has to move more air.

DC7020 uses a 70×70mm mounting footprint and 20mm overall depth. For equipment engineers, this combination is useful when the mounting area is already defined and the decision moves to available internal clearance, component obstruction and required exchange of air. Its maximum free-air rating reaches 43.20CFM at 5,000RPM.
A correct selection starts with the power rail and a realistic operating point. Separate 12V and 24V model families are offered, each with three speed grades. Sleeve or ball-bearing versions can be specified, and the available signal options should be agreed with the equipment control interface before OEM release.
Airflow and Static Pressure Across Three Speed Grades
Use the P-Q curves to compare the 3,000, 4,000 and 5,000RPM grades where pressure loss is present. As system resistance rises, the flow available at the installed operating point generally decreases. At the rated endpoints, the 5,000RPM variant is specified at 43.20CFM maximum free-air flow and 6.83mmH₂O maximum static pressure. These are different ends of its P-Q curve, not one simultaneous operating condition.

Industrial Equipment Ventilation and Heat Sink Applications
DC7020 can be considered where a 70mm opening, 20mm clearance and a defined airflow requirement meet. The equipment air path and supply voltage determine whether a given version is suitable.
Get Cooling Support
Industrial Drive Electronics
Power devices and drive boards can create local hot spots inside compact motor-control assemblies. Positioning a 70mm fan near the required air path can support convective removal of heat, provided the enclosure accommodates the 20mm frame and the selected operating point is sufficient.

Heat-Sink Ventilation Channels
Compact heat-sink assemblies often narrow the free airflow area. In this application, the important question is not peak CFM alone but whether a selected DC7020 speed grade can maintain suitable flow through the fins and nearby duct openings.

Power Conversion Enclosures
Converters and DC power modules may have concentrated heat sources behind inlet grilles. A DC ventilation fan configuration can be evaluated for cabinet air exchange, with attention to grille obstruction, component spacing and the rated 12V or 24V supply.

Equipment Exhaust Openings
When hot air must leave a compact enclosure through a specific opening, an appropriately oriented DC exhaust fan arrangement may support the intended flow path. Confirm airflow direction, outlet clearance and whether the enclosure needs intake make-up air.

Rack-Mounted Control Modules
Modular control assemblies can be densely populated with boards, connectors and wiring harnesses. The 20mm thickness may suit a designated fan bay when installation depth is available; model selection should also account for inlet restrictions and cable routing.
YCCFAN DC7020 20mm Frame Fit and Operating Demonstration
See the 70×70×20mm frame from the front and side, then inspect airflow direction and the space required for mounting screws and wiring. A running demonstration can show the fan arrangement; it should not be presented as a measured airflow test unless calibrated test equipment is used.
DC7020 is a 70×70×20mm axial DC fan family covering 12V and 24V operation with three speed grades from 3,000 to 5,000RPM. Product videos for this series should present the actual installed depth, mounting-hole pitch and connector orientation so that engineers can confirm mechanical fit before sampling.
When comparing performance on camera, each recording should state the voltage and speed configuration being demonstrated, because airflow and noise differ across the range. Contact YCCFAN for sample requests or the latest test footage of the DC7020 series.
DC7020 Replacement, Ventilation and Electrical FAQs
A: Only if the enclosure has 20mm of clearance and the electrical and mechanical interfaces match. Check mounting-hole positions, airflow direction, rated voltage, current, connector and any speed-feedback requirements before replacement.
A: Not necessarily. 43.20CFM is the maximum free-air value of the 5,000RPM version. The operating airflow falls according to the resistance of the installed grille, heat sink and enclosure air path; use the P-Q curve for selection.
A: Not without confirming the equipment supply. DC7020 has separate 12V and 24V rated versions. Choose the model matching the available DC voltage and verify the rated current, wiring polarity and connector before installation.
A: The system resistance increases, which can reduce the installed airflow. Reassess the selected speed grade using the characteristic curve and the planned airflow route rather than relying on the fan's free-air performance alone.
A: No such assumption should be made. PWM, FG and RD are listed as available functional options, and the requested interface must be confirmed for the ordered configuration. Match control signals and wiring to the host equipment.
A: Share the supply voltage, target airflow at expected resistance, available 70×70×20mm mounting space, acoustic limit, bearing preference, cable/connector details, optional signals and estimated order volume. This helps YCCFAN identify a suitable model configuration.

Can't Find the Perfect Fan?
We offer customization services from wire length to full mold design. Get a solution in 48 hours.
Request a DC7020 Sample or Custom Solution