DC8020 80x80x20 DC Fan
DC8020 80x80x20 DC Fan

DC8020 80x80x20 DC Fan

Four speed choices in a 20mm-deep frame, with 12V and 24V models for different power supplies.

The DC8020 DC fan gives designers eight ways to match airflow and pressure to an equipment design without changing the mounting size. Its four speed levels run from 2,500 to 5,500 RPM. Across the range, airflow spans 24.52–53.94 CFM and static pressure spans 2.20–8.95 mmH₂O. Start with the available voltage, then compare the performance curve, current and noise of the speed level you need.

Rated voltage: 12 VDC / 24 VDC

Size: 80×80×20mm

Airflow: 24.52–53.94 CFM

Static pressure: 2.20–8.95 mmH₂O

Speed: 2,500 / 3,500 / 4,500 / 5,500 RPM

Find Your DC8020 Model

DC8020 Specifications

Find the required voltage, then compare four speed levels by current, airflow, pressure and noise.

ModelVoltage
(VDC)
Current
(A)
Speed
(RPM)
Airflow
(CFM)
Pressure
(mmH₂O)
Noise
(dBA)
Weight
(g)
YDD8020X12F12 VDC0.365,50053.948.9546.6159
YDH8020X12F12 VDC0.214,50044.146.4740.1159
YDM8020X12F12 VDC0.113,50034.334.0633.9259
YDL8020X12F12 VDC0.042,50024.522.2025.3459
YDD8020X24F24 VDC0.195,50053.948.9546.6159
YDH8020X24F24 VDC0.124,50044.146.4740.1159
YDM8020X24F24 VDC0.063,50034.334.0633.9259
YDL8020X24F24 VDC0.032,50024.522.2025.3459

YCCFAN 80mm Fan Performance and Configuration Options

A consistent mounting size, four performance levels and two supply voltages help narrow the choice to a specific model.

80x80x20mm DC fan

20mm Depth for a Defined Mounting Space

The fan measures 80×80×20mm. Where a design allows an 80mm square mounting area and 20mm of fan depth, DC8020 provides four performance levels without a change in nominal frame size.

high speed 12V DC fan option

High Speed 12V DC Fan Option

YDD8020X12F runs at 5,500 RPM and lists 53.94 CFM airflow, 8.95 mmH₂O static pressure, 0.36 A current and 46.61 dBA noise. Compare other speed levels when different performance requirements are needed.

12V and 24V DC fan options

Two Voltage Groups with Matching Speed Levels

Each speed level has a 12 VDC and a 24 VDC model. Designers can select the equipment supply voltage first, then compare airflow, pressure, current and noise within the relevant voltage group.

bearing and function choices

Bearing and Function Choices

Ball bearing and CycleSeal bearing versions are available. FG, RD, PWM, auto restart and polarity protection functions can also be specified according to project requirements.

YCCFAN DC8020 Product Overview

YCCFAN DC8020 80x80x20mm DC fan dimension drawing

DC8020 is an 80×80×20mm DC fan designed for equipment requiring an 80mm mounting size with additional installation depth. It provides 12V and 24V options with four speed levels, allowing designers to compare airflow, static pressure and noise performance according to system requirements.

With airflow ranging from 24.52 to 53.94 CFM and static pressure from 2.20 to 8.95 mmH₂O, DC8020 supports different cooling demands within the same frame size. Ball bearing and CycleSeal bearing options, together with FG, RD, PWM, auto restart and polarity protection functions, provide flexible configuration choices for equipment designs.

DC8020 Airflow & Static Pressure Performance Curve

Use the curve for the selected speed to assess how much airflow remains as system resistance increases.

DC8020 has separate curves for 2,500, 3,500, 4,500 and 5,500 RPM. Locate the expected operating range of the assembled equipment on the relevant curve before choosing a model. Maximum airflow and maximum static pressure occur at different points, so neither pair of maximum values describes one operating point.

YCCFAN DC8020 airflow and static pressure performance curve

Applications in 80mm 12v dc fan

Supporting cooling applications in electronic enclosures, power equipment, communication systems, industrial control equipment, and cabinets requiring an 80mm mounting size with a 20mm fan depth.

Get Cooling Support
DC8020 electronic enclosure cooling fan

Electronic Enclosures

DC8020 can be evaluated for an enclosure with a matching mounting position and sufficient depth. Check the inlet, outlet and internal components to understand the resistance the fan will face.

DC8020 power and control equipment cooling fan

Power and Control Equipment

The 12V and 24V groups allow designers to match the fan to the equipment supply. Use the current and performance figures of the exact model when planning the electrical and thermal design.

DC8020 communication equipment cooling fan

Communication Equipment

Four speed levels let designers compare airflow and pressure for a matching installation space. Where monitoring or speed control is required, state the needed signal or function when requesting the fan.

DC8020 cabinet cooling fan

Cabinet Cooling Fan Fit

A cabinet with an 80×80mm mounting cutout and room for a 20mm-deep frame can be assessed for DC8020. Compare the fan curve with the resistance of the complete ventilation path before choosing a speed.

DC8020 industrial control equipment cooling fan

Industrial Control Equipment

DC8020 can support industrial control equipment requiring stable airflow inside compact enclosures. The four speed options help designers select suitable airflow and pressure performance according to system requirements.

YCCFAN DC8020 80×80×20mm Fan Video Showcase

Watch DC8020 in operation to see its frame, mounting form and rotating blades. The video helps assess physical fit; use the dimension drawing and performance curves when selecting the final model.

DC8020 shows its frame structure, mounting form and rotating blades in operation, helping users understand the physical installation characteristics before selecting a model.

Use the dimension drawing and performance curves together with the video when evaluating the suitable DC8020 configuration for your equipment design.

DC8020 Selection & Specification FAQs

Will DC8020 fit my 80mm mounting position?

A: Check the 80×80×20mm overall size and the 71.5±0.3mm mounting-hole spacing shown in the drawing. Allow clearance around the inlet, outlet and wiring before replacing an existing fan.

How do I choose between the 12V and 24V versions?

A: Match the rated voltage to the equipment supply first. Both voltage groups offer the same four speed levels, so you can compare current, airflow, pressure and noise within the appropriate group.

Which speed should I consider when airflow paths are restrictive?

A: Start with the 4,500 and 5,500 RPM curves, then compare their airflow at the resistance expected in the assembled equipment. The 5,500 RPM models list the highest maximum static pressure, 8.95 mmH₂O, but the final choice depends on the operating point and acceptable noise.

What changes when I select the 5,500 RPM model?

A: It provides the highest listed airflow and static pressure in the DC8020 range: 53.94 CFM and 8.95 mmH₂O. It also has the highest listed noise level, 46.61 dBA; check current draw for the chosen voltage before selection.

Which option suits a lower noise target?

A: The 2,500 RPM models have the lowest listed noise level at 25.34 dBA. Check whether their 24.52 CFM airflow and 2.20 mmH₂O maximum static pressure meet the equipment’s cooling requirement; otherwise, compare the 3,500 RPM curve.

What should I specify for bearing and control options?

A: State the supply voltage, target speed, ball or CycleSeal bearing choice, and any required PWM, FG or RD function. Confirm the requested combination for the exact model before ordering.

Can't Find the Perfect Fan?

We offer customization services from wire length to full mold design. Get a solution in 48 hours.

Request Custom Solution
TOP